Differences between revisions 12 and 15 (spanning 3 versions)
Revision 12 as of 2009-02-12 18:47:32
Size: 3347
Editor: UlrikeHeiter
Comment: corrected obs wave range
Revision 15 as of 2009-02-12 23:05:54
Size: 4188
Editor: UlrikeHeiter
Comment: added explanation for number of lines in obs list
Deletions are marked like this. Additions are marked like this.
Line 44: Line 44:
A separate list with observed wavenumbers from Phillips (Bertrand Plez, priv. comm. 17 Sep 2008) and calculated other values from Plez (from the list with lambda-doubled lines merged), will be generated. Reference: Davis et al. 1986, ApJ 309, 449. A separate list with observed wavenumbers from Phillips (Bertrand Plez, priv. comm. 17 Sep 2008) and calculated other values from Plez (from the list with lambda-doubled lines merged), has been generated. Reference: Davis et al. 1986, ApJ 309, 449.
Line 46: Line 46:
The original list is at /h19/ulrike/Molecules/Data/TiO/TiO-Phillips-OBS.dat

It contains about 35000 lines in the alpha, beta, gamma, gammaprime systems
It contains lines in the alpha, beta, gamma, gammaprime systems
Line 56: Line 54:
The original list is at /h19/ulrike/Molecules/Data/TiO/TiO-Phillips-OBS.dat and has over 35000 lines.
Line 59: Line 59:
There are a few "double" lines with same quantum numbers and branch names (but different wavenumbers). The wavenumbers for these will be averaged. There are a few "double" lines with same quantum numbers and branch names (but different wavenumbers). The wavenumbers for these have been averaged for the converted list.

The converted list (ascii format, same format as calculated list) is at /h19/ulrike/Molecules/Data/TiO/TiO-Phillips-OBS-vald.asc and has 32574 lines.

The conversion code is at /h19/ulrike/Molecules/Data/TiO/tio_phillips_to_vald_ascii.f

The list has been sorted by wavelength after running the conversion code.

Differences between observed and calculated wavelengths, O-C: min=-5.4Å, max=1.7Å.

Explanation for different numbers of lines in original and converted list:
P3,Q3,R3 lines in the gamma prime system (H, X-B) are "double", because of resolved lambda doubling in the calculated list (+958 lines). 3341 lines in the gamma prime system where the branch name contains C or D are not in the calculated list. 157 other lines are not in the calculated list (all with J,,low,,<=4).

TiO data

TiO line lists calculated by Bertrand on 29 May 2008. The files are in Uppsala at /h5/plez/TiOVALD/linelist/linelist??_all.dat.gz
For files with lambda-doubled lines merged see below.

Number of lines:

Isotope

Nmerg

Norig

46

8193347

11140205

47

8194614

11141521

48

8195512

11142777

49

8196355

11143980

50

8197133

11144857

total

40976961

55713340

Norig ... original lists
Nmerg ... lambda-doubled lines merged

Transitions in BP's line list

BP_transitions.png

Lambda doubling

-- BertrandPlez 28 Jan 2009:

Some transitions are affected by Lambda-doubling. In that case there are 2 sublevels that give rise to transitions, and if the separation is large enough, they appear in the list as 2 lines with the same parameters except for the parity of the upper and lower level, and a slightly different wavenumber. The degeneracy of these sublevels is 2*J+1. When the Lambda-doubling is too small there are 2 lines with exactly the same data (except the parities). One way to compact the list is to merge these lines and double the gf-value 2*(2*J+1)*f.

For some transitions Lambda-doubling does not exist (if Lambda=0, i.e if one of the states is a sigma state).

-- UlrikeHeiter 2009-02-06 08:37:27 - Lambda-doubled lines have been merged according to BP's comment above.

The new files are in Uppsala at /h19/ulrike/Molecules/Data/TiO/linelist??_all_nodoubling.dat.gz

The merging code is at /h19/ulrike/Molecules/Data/TiO/tio_plez_rm_doubling.pro

Observed wavenumbers

A separate list with observed wavenumbers from Phillips (Bertrand Plez, priv. comm. 17 Sep 2008) and calculated other values from Plez (from the list with lambda-doubled lines merged), has been generated. Reference: Davis et al. 1986, ApJ 309, 449.

It contains lines in the alpha, beta, gamma, gammaprime systems with range:

wavenumber(cm-1)

wavelength(Å)

20997.64

4762.440

11383.24

8784.845

Isotope: 48Ti (see Davis et al. 1986, IV.a p. 452)

The original list is at /h19/ulrike/Molecules/Data/TiO/TiO-Phillips-OBS.dat and has over 35000 lines.

Content: "Obs", vupp, vlow, Jlow, "+", branch, ".0000E+00", wavenumber, ".000", system

There are a few "double" lines with same quantum numbers and branch names (but different wavenumbers). The wavenumbers for these have been averaged for the converted list.

The converted list (ascii format, same format as calculated list) is at /h19/ulrike/Molecules/Data/TiO/TiO-Phillips-OBS-vald.asc and has 32574 lines.

The conversion code is at /h19/ulrike/Molecules/Data/TiO/tio_phillips_to_vald_ascii.f

The list has been sorted by wavelength after running the conversion code.

Differences between observed and calculated wavelengths, O-C: min=-5.4Å, max=1.7Å.

Explanation for different numbers of lines in original and converted list: P3,Q3,R3 lines in the gamma prime system (H, X-B) are "double", because of resolved lambda doubling in the calculated list (+958 lines). 3341 lines in the gamma prime system where the branch name contains C or D are not in the calculated list. 157 other lines are not in the calculated list (all with Jlow<=4).

beta system:

v-v

branch

Jlow range

Jlow missing

0-0

P

4<=Jlow<= 99

94

1-1

P

2<=Jlow<=100

66,88,91,92,93,95

2-2

P

2<=Jlow<= 90

8,10,12,14,76,81,83

0-0

Q

2<=Jlow<=100

4

1-1

Q

1<=Jlow<=100

2,4,96

2-2

Q

3<=Jlow<=100

7,78,82,83,84,89,90,91

0-0

R

2<=Jlow<=100

1-1

R

2<=Jlow<= 98

7

2-2

R

2<=Jlow<= 92

5,26,42,62,64,70,74,75,84

ValdWiki: TiO (last edited 2012-05-04 17:16:40 by UlrikeHeiter)