Size: 1965
Comment:
|
Size: 2013
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
## Please edit system and help pages ONLY in the master wiki! ## For more information, please see MoinMoin:MoinDev/Translation. ## IMPORTANT NOTE: ## When you use this page as a template for creating your project page: ## * please remove all lines starting with two hashes (##) ## * except the acl line, please keep that, but remove one hash, so it reads #acl ... ## * fix the acl line so it has the correct page instead of the sample Project/...Group ##acl Project/AdminGroup:admin,read,write,delete,revert Project/ReadWriteGroup:read,write Project/ReadGroup:read ##master-page:Unknown-Page ##master-date:Unknown-Date |
## page was renamed from VALD confuguration file |
Line 13: | Line 4: |
Changes in VALD3 configuration file. | = VALD configuration file (VALD3 version) = |
Line 15: | Line 6: |
The VALD configuration file describes the data files. One line corresponds to a single data file. The first line contains wavelength window and the reference wavelength for line identification, maximum ionization stage and the maximum excitation potential for the lower level in eV. Wavelength window scales with the wavelength but not more then by a factor of 100: dwl = min(max(dwl*wl/wl_ref, dwl_ref*0.01), dwl_ref*100). |
The VALD configuration file sets a few global extraction parameters, and lists the data files to be included for extraction. The first line contains the wavelength window and the reference wavelength for line identification, the maximum ionization stage, and the maximum excitation potential for the lower level in eV. The reference wavelength {{{wl_ref}}} is used to scale the wavelength window when comparing lines from different data files. The maximum scaling factor is 100: {{{wl_window = min(max(wl_window_ref * wl / wl_ref, wl_window_ref*0.01), wl_window_ref*100)}}}. |
Line 21: | Line 9: |
Any consecutive line starting with semi-column are interpreted as comments. Each line starts with filename complete with a path relative to VALD home directory. Next parameter is a unique number of the line list in the configuration file. This number is only used for association of the list name and extracted data field and thus does not have to be consistent between different configuration files. The two next entries are give range of species included in the file using the VALD unique species number. This is the reason why species number in the VALD species list must be monotonous! |
Any subsequent line starting with semicolon is interpreted as a comment line. Otherwise, one line corresponds to a single data file. Each line starts with the filename includeing a path relative to the VALD home directory. The next parameter is a unique number of the line list in the configuration file. This number is only used for associating the list name with the extracted data field, and thus does not have to be consistent between different configuration files. The two next entries give the range of species included in the file using the VALD unique species number. This is the reason why the species number in the VALD species list must be monotonous! |
Line 30: | Line 13: |
The next entry is new: it is a flag that indicates that the list can be merged (0) or is exempt from any merger (1). |
The next entry is new compared to VALD2: it is a flag that indicates that the list can be merged (0) or is exempt from any merger (1). |
Line 33: | Line 15: |
The rest of the line is as before: 9 weights starting from the wavelength and the short name of the line list. |
The rest of the line is as for VALD2: nine weights used for merging data for the same transition from different files (integer numbers for wavelength, gf-value, upper level energy, lower level energy, Landé factor, radiative-, Stark-, and Van der Waals broadening, and the level designation), followed by the short name of the line list. An example for a VALD3 configuration file can be found [[http://www.astro.uu.se/valdwiki/VALD3linelists?action=AttachFile&do=view&target=VALD3_obs.cfg|here]]. |
VALD configuration file (VALD3 version)
The VALD configuration file sets a few global extraction parameters, and lists the data files to be included for extraction. The first line contains the wavelength window and the reference wavelength for line identification, the maximum ionization stage, and the maximum excitation potential for the lower level in eV. The reference wavelength wl_ref is used to scale the wavelength window when comparing lines from different data files. The maximum scaling factor is 100: wl_window = min(max(wl_window_ref * wl / wl_ref, wl_window_ref*0.01), wl_window_ref*100).
Any subsequent line starting with semicolon is interpreted as a comment line. Otherwise, one line corresponds to a single data file. Each line starts with the filename includeing a path relative to the VALD home directory. The next parameter is a unique number of the line list in the configuration file. This number is only used for associating the list name with the extracted data field, and thus does not have to be consistent between different configuration files. The two next entries give the range of species included in the file using the VALD unique species number. This is the reason why the species number in the VALD species list must be monotonous!
The next entry is new compared to VALD2: it is a flag that indicates that the list can be merged (0) or is exempt from any merger (1).
The rest of the line is as for VALD2: nine weights used for merging data for the same transition from different files (integer numbers for wavelength, gf-value, upper level energy, lower level energy, Landé factor, radiative-, Stark-, and Van der Waals broadening, and the level designation), followed by the short name of the line list.
An example for a VALD3 configuration file can be found here.